Sine Sweep Linear 20Hz to 20000Hz Test Oscillator | Human Audio Spectrum | 1 Hour Signal Continuous

Details
Title | Sine Sweep Linear 20Hz to 20000Hz Test Oscillator | Human Audio Spectrum | 1 Hour Signal Continuous |
Author | Your Gateway to Relaxation |
Duration | 1:05:50 |
File Format | MP3 / MP4 |
Original URL | https://youtube.com/watch?v=56nPVUVmfr8 |
Description
Welcome to the COMFORT ZONE. Thank you very much for Listening and SUBSCRIBING! And if you LIKE it, please thumbs up!
Sinusoidal wave going trough entire human audio spectrum, starting at 20Hz and ending at 20kHz. Note that the frequency increases exponentially, the idea was to increase the frequency by constant fraction of currently played frequency rather than by a constant value (which would result in clearly noticeable fast change at lower frequencies and nearly no change at higher frequencies). Enjoy.
Note: This wave has the same volume level measured by acoustic pressure all the time, however human sound perception differs depending on frequency. For lower frequencies (below 1kHz) you might want to increase your volume, but don't forget to lower it later to avoid damage to your hearing.
If you don't hear anything below 40-50Hz even at full volume your audio hardware is probably incapable of playing lowest frequencies. You might want to try to listen on the headphones in such case. Also if you stop hearing sound somewhere between 10kHz - 20kHz - do not increase your volume for safety reasons. Every human hears a bit differently and have different hearing thresholds. Hearing range also changes with age. Younger people can usually hear higher frequencies.
With the black screen white noise, you'll benefit by keeping the room dark while sleeping, saving battery life on your phone or tablet, reducing data usage and not having to worry about screen burn-in. The black screen 10 hours video uses less data, which is helpful especially when traveling. (You can lower the quality settings on YouTube playback since there is no image.)
For more white noise sounds to help you sleep, please check out:
👉 Water Sounds for Sleep: https://youtu.be/Z-K_QOs6T70
👉 Beach Sounds for Sleeping: https://youtu.be/EHp2uHsSfVY
👉 Relaxing Walk in the Mountain: https://youtu.be/qfhdUGnzx0s
Please subscribe to our channel: https://www.youtube.com/channel/UCz2JRQhpIh03DksmUT7dzpg
A sweep generator is a piece of electronic test equipment similar to, and sometimes included on, a function generator which creates an electrical waveform with a linearly varying frequency and a constant amplitude. Sweep generators are commonly used to test the frequency response of electronic filter circuits. These circuits are mostly transistor circuits with inductors and capacitors to create linear characteristics.
Sweeps are a popular method in the field of audio measurement[1] to describe the change in a measured output value over a progressing input parameter. The most commonly-used progressive input parameter is frequency varied over the standard audio bandwidth of 20 Hz to 20 kHz.
A glide sweep (or chirp) is a continuous signal in which the frequency increases or decreases logarithmically with time. This provides the complete range of testing frequencies between the start and stop frequency. An advantage over the stepped sweep is that the signal duration can be reduced by the user without any loss of frequency resolution in the results. This allows for rapid testing. Although the theory behind the glide sweep has been known for several decades, its use in audio measuring devices has only evolved over the past several years. The reason for this lies with the high computing power required.
In a stepped sweep, one variable input parameter (frequency or amplitude) is incremented or decremented in discrete steps. After each change, the analyzer waits until a stable reading is detected before switching to the next step. The scaling of the steps is linear or logarithmic. Since the settling time of different test objects cannot be predicted, the duration of a stepped sweep cannot be determined exactly in advance. For the determination of amplitude or frequency response, the stepped sweep has been largely replaced by the glide sweep. The main application for the stepped sweep is to measure the linearity of systems. Here, the frequency of the test signal is kept constant while the amplitude is varied. Typically the amplitude and distortion of the device under test are measured. This is also referred to as an "amplitude sweep".
In the case of a time sweep, the x-axis represents time. Again the y-axis represents a measured value, e.g. amplitude. The change in the measured value is observed over time. For example, how does the response of the device under test change over a long period?
A rarely used special form of the stepped sweep is the table sweep. Here the input signal is produced from a table as a sequence of any frequency and amplitude pairs.